China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories

Product Details
Customization: Available
Certification: ISO9001
Type: Electric Coil
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
  • China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories
  • China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories
  • China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories
  • China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories
  • China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories
  • China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories
Find Similar Products

Basic Info.

Model NO.
ADK11-15A-02E
Form
Heating Wire
Shape
Plate
Material Quality
Copper
Available Fluids
Oil, Water, Warm Water
Alias
High Temperature Valve
Solenoid Valve Power Supply
220V
Transport Package
Export Packing
Specification
73*43*58.4
Trademark
CKD
Origin
Japanese
Production Capacity
999

Packaging & Delivery

Package Size
7.30cm * 4.30cm * 5.84cm
Package Gross Weight
8.000kg

Product Description

1,CKD solenoid valve safety:

(1)Corrosive media: It is recommended to use plastic king solenoid valves and all stainless steel; For strongly corrosive media, isolation diaphragm type must be selected. For example, CD-F.Z3CF. For neutral media, it is also advisable to use copper alloy as the valve casing material for electromagnetic valves. Otherwise, rust debris often falls off in the valve casing, especially in situations where the action is not frequent. Ammonia valves cannot be made of copper.

(2)Explosive environment: Corresponding explosion-proof grade products must be selected. Waterproof and waterproof measures should be adopted for outdoor installation or dust prone situations Dust species.

(3)The nominal pressure of the solenoid valve should exceed the maximum working pressure inside the pipe.
CKD solenoid valve safety:
1. Medium characteristics
1.1 Choose different types of solenoid valves for gas, liquid or mixed states, such as ZQDF for air, ZQDF-Y for liquid, and ZQDF-2 (or -3) for steam, otherwise it may cause malfunction. The ZDF series multifunctional solenoid valve can be used universally for gas and liquid. It is best to inform the media status when ordering, so that installation users do not need to adjust the mode again.

1.2 Different specifications of products with different medium temperatures, otherwise the coil will burn out, the sealing components will age, and the service life will be seriously affected

1.3 Medium viscosity, usually below 50cSt. If it exceeds this value and the diameter is greater than 15mm, use the ZDF series multifunctional solenoid valve for special orders. High viscosity solenoid valve with a diameter less than 15mm

1.4When the cleanliness of the medium is not high, a backwash filter valve should be installed in front of the solenoid valve. When the pressure is low, a direct acting diaphragm type solenoid valve can be selected, such as CD-P

1.5If the medium is directional flow and reverse flow ZDF-N and ZQDF-N are not allowed, bidirectional flow is required. Please make special requirements

1.6 The medium temperature should be selected within the allowable range of the solenoid valve
China Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine AccessoriesChina Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine AccessoriesChina Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine AccessoriesChina Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine AccessoriesChina Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine AccessoriesChina Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine AccessoriesChina Factory Direct Sales CKD Japanese Burner Solenoid Valve Adk11-15A-02e Boiler High-Temperature Valve Combustion Machine Accessories

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now